About us   Offer   Contact

TKE marine pumps

   Description
   Operating range
   Materials
   Acceptance
   Technical data
TKE marine pumps

Description

The TKE pumps are vertical two-cylinder force pumps of double operation.
In standard execution the TKE pumps are driven by an electric motor of direct current or alternating current of frequency 50 Hz. At the customer's request GZUT also manufactures and delivers the pumps designed to work in the systems supplied with alternating current of frequency 60 Hz.
Principal dimensions of the pumps and connection pipes are given on the chart and drawings.
The TKE pumps are designed to pump fresh water, sea water and oil of viscosities up to 5oE (corresponding to 38,2 centistokes). In case of using the TKE pumps for other media you are requested to consult the producer.


GZUT recommends isutalling the TKE pumps in the following systems:

  • bilge
  • ballast
  • fire
  • rest
  • as auxiliary pumps.

The TKE pumps can operate in the systems of manual, automatic and remote control.

Operating range

The TKE pumps are designed to pump liquids in the following
temperature ranges:

  • for fresh water and oil - up to 60oC
  • for sea water - up to 45oC.
The capacity ranges and pumping heights for different TKE pump sizes are given on the chart and diagram.


Performance curves of TKE pumps

Performance curves of TKE pumps

Materials

The TKE pump casing is made of grey cast iron. All the parts of the pump being in contact with the pumped medium are made of sea - water resistant materials.

Acceptance

The TKE pumps are manufactured in accordance with the regulations and requirements of the following clas-sification societies:

  • Polish Register of Shipping
  • Lloyd's Register of Shipping
  • U.S.S.R. Register of Shipping.

Technical data

Pump
type
Pump delivery
Q [m3/h]
Useful delivery
head Hu[mH2O]
Pump
speed [rpm]
Weight without
motor [kg]
Power at coupling
[kW]
10TKE20 10 20 145 410 1.02
10TKE35 35 1.70
10TKE50 50 2.60
16TKE20 16 20 145 420 1.60
16TKE30 30 2.35
16TKE45 45 3.50
16TKE60 60 4.70
25TKE20 25 20 145 430 2.40
25TKE30 30 3.60
25TKE45 45 5.40
25TKE60 60 7.20


Pump
type
Dimension [mm] Inlet and Outlet
connection pipes dimensions [mm]
No of
holes
Amax C fF H M O S U
B D G J N R T --- a b d g e i
10TKE 1600 425 23 250 370 450 150 300 200 160 80 18 20 8
1250
16TKE 1650
1270 150 610 210 430 390 750 --- 195 145 65 18 20 4
25TKE 1650
...

Dimensions of TKE pumps

Dimensions of TKE pumps